SBIR/STTR Research Award
Development and Pre-Clinical Testing of a Smart Defibrillator Algorithm for Treatment of Cardiac Arrhythmias
Award amount
$251,746Program and phase
SBIR · Phase IAward year
2021Award details
- Awarding agency
- Department of Health and Human Services
- Branch
- National Institutes of Health
- Recipient company
- Arrhythmia Dynamics LLC
- Proposal award date
- 2021-07-15
- Contract end date
- 2022-03-31
- UEI
- KP2FY5MTN1A5
- Solicitation number
- PA20-260
- Topic code
- NHLBI
Research abstract
Project Summary / Abstract:
Significance: Each year 300,000 to 400,000 patients experience sudden cardiac death in the United States. For patients
at risk, implantable cardiac defibrillators (ICDs) improve survival, largely through the delivery of high energy shocks to
restore sinus rhythm. While high energy shocks are clearly life-saving, they are not necessarily benign. Patients receiving
high energy shocks have increased mortality and programming the device to reduce the number of shocks delivered can
improve mortality. High energy shocks are associated with myocardial stunning, injury, and cell death. In addition, they
are painful to the patient, are associated with significant healthcare costs, and result in more rapid battery depletion.
Innovation: Arrhythmia Dynamics, LLC is developing the IntelliSync ICD control algorithm which enable ICDs to save lives
while minimizing the use of harmful and damaging high energy shocks. IntelliSync will do this in two ways: 1)
recognizing ventricular arrhythmia episodes which have high probability of terminating on their own without therapy;
and 2) making the delivery of low energy defibrillation more likely to terminate the arrhythmia by optimally timing it to a
period of high baseline synchronization in the ventricular chambers.
Approach: In this grant we propose testing the feasibility of these algorithms in computational and rat models of
ventricular fibrillation. In order to be clinically relevant, the algorithms must function and guide the defibrillator’s
decision quickly. The goal of our IntelliSync algorithm are 2-fold: 1) Analyze the first 6-8 seconds of an arrythmia within 2
seconds, recognize patterns of regional coupling within the heart that herald imminent arrhythmia termination. If
identified, the algorithm would trigger the ICD to wait for VF to terminate on its own, and only deliver therapy after a
time-out period has occurred. 2) Measure patterns of coupling within the heart and time low energy therapy (if
appropriate) to a period of high synchronization when it is more likely to succeed. IntelliSync may also work for atrial
fibrillation (AF) and could make an atrial defibrillator palatable if shocks above the pain threshold could be avoided.
Aim 1 (months 1-6): Optimize algorithm performance in computational models of ventricular fibrillation
Sub-aim 1A: Determine minimum spatiotemporal resolution needed to represent high density intracellular voltage maps.
Sub aim 1B: Identify threshold of change in the RQA variable Entropy which predicts imminent termination.
Sub-aim 1C: Demonstrate that low energy therapies can be effectively timed to periods of greater tissue synchronization.
Aim 2 (months 3-9): Demonstrate feasibility of delivering low energy therapy timed to period of high synchronization
based on real-time calculations in a small animal model of VF
Sub aim 2A: Demonstrate that synchrony measured from limited epicardial sensors are representative of full optical maps
Sub-aim 2B: Establish threshold values for the RQA variable Entropy which identify episodes likely to self-terminate
Sub-aim 2C: Prospectively test threshold value of Entropy from Aim 2B.
Sub-Aim 2D: Demonstrate feasibility of performing real-time RQA calculations to guide delivery of low energy therapy.Project Narrative:
Arrhythmia Dynamics, LLC is developing the IntelliSync ICD control algorithm which enable ICDs to save lives will
minimizing the use of harmful and damaging high energy shocks. Each year 300,000 to 400,000 patients experience
sudden cardiac death in the United States. For patients at risk, implantable cardiac defibrillators (ICDs) improve survival,
largely through the delivery of high energy shocks to restore sinus rhythm. While high energy shocks are clearly life-
saving, they are not benign. High energy shocks are associated with myocardial stunning, injury, and cell death and
patients receiving them have increased mortality. The IntelliSync ICD control algorithm which enable ICDs to save lives
will minimizing the use of harmful and damaging high energy shocks by 1) recognizing ventricular arrhythmia episodes
which have high probability of terminating on their own without therapy; and 2) timing low energy defibrillation to
periods of synchronization where it is more likely to be effective.
Technology keywords
Not reported
Awards with the same topic code
Verified by an exact topic code match. This is not a text-similarity match.
- DUCTUS ARTERIOSUS STENT TO IMPROVE CONGENITAL HEART DEFECT MORTALITY
- Head Up CPR and Aortic Occlusion to Improve Survival after Refractory Cardiac Arrest
- Free-Breathing Dynamic Cardiopulmonary Function Imaging System to use with Xenon MRI
- The Next Wave of Asthma Therapeutics
- Bearingless flux reversal motor for neonatal and pediatric extracorporeal life support applications