Feasibility Study of Innovative Fiber Optic Technology to Suppress Inappropriate Discharges from Implantable Cardioverter-Defibrillators
Award amount
$251,923Program and phase
STTR · Phase IAward year
2021Award details
- Awarding agency
- Department of Health and Human Services
- Branch
- National Institutes of Health
- Recipient company
- CHELAK MEDICAL SOLUTIONS INC
- Proposal award date
- 2021-07-01
- Contract end date
- 2022-03-31
- UEI
- QJBDHTAKKHV3
- Solicitation number
- PA20-265
- Topic code
- NHLBI
Research abstract
Project Summary
Implantable Cardioverter/defibrillators (ICDs) have been proven to the most effective therapy to
reduce mortality from sudden cardiac death. Today’s ICD technology exclusively relies on
sophisticated algorithmic analysis of cardiac electric signals (electrograms, EGM) sensed by the
ICD to detect fatal cardiac arrhythmias, such as ventricular tachycardia (VT) and ventricular
fibrillation (VF), that trigger discharge of electrical energy (ICD shock) to restore normal rhythm.
Despite decades of continuing effort and incremental technological advances, inappropriate
shock (IAS), erroneously triggered by nonfatal events, remains a significant problem and
represents an unmet clinical need. IAS often occurs during nonfatal events that are associated
with stable hemodynamic status and most commonly include (1) electrical noises, from
electromagnetic interference (external noise) or ICD lead fracture (internal noise), and (2)
nonfatal tachyarrhythmias (TA) such as hemodynamically stable atrial fibrillation (AF) with rapid
ventricular response
. The objective of the project is to test the feasibility and eventual
commercialization of an innovative technology with fiber optic sensors in the existing ICD
system that assess the hemodynamic stability during arrhythmias and thereby reduce IAS. The
proposed research in Phase I is to evaluate the feasibility of this novel technology in a swine
model to determine hemodynamic stability during tachyarrhythmia, thereby separating
hemodynamically stable TAs from those that are unstable, and will specifically focus on testing
the feasibility of optical sensors embedded in the existing ICD system in assessing
hemodynamics through detecting changes in cardiac strain parameters (Aim 1), the feasibility of
such optical sensors in identifying electrical noises based on unchanged hemodynamics (Aim
2),
and the feasibility of such optical sensors in differentiating hemodynamically stable AF with
rapid ventricular response from unstable AF and from ventricular fibrillation (Aim 3).Public Health Relevance Statement (Project Narrative)
Implantable cardioverter/defibrillator (ICD) represents the most effective treatment for sudden
cardiac arrest but may cause inappropriate ICD shocks (IAS) that significantly increase
morbidity and healthcare costs and
is associated with increased mortality
. The proposal seeks
to develop innovative fiber optic sensor technology that can be incorporated into existing ICD
system and prevent IAS by hemodynamic assessment prior to ICD shocks.
Technology keywords
Not reported
Awards with the same topic code
Verified by an exact topic code match. This is not a text-similarity match.
- DUCTUS ARTERIOSUS STENT TO IMPROVE CONGENITAL HEART DEFECT MORTALITY
- Head Up CPR and Aortic Occlusion to Improve Survival after Refractory Cardiac Arrest
- Free-Breathing Dynamic Cardiopulmonary Function Imaging System to use with Xenon MRI
- The Next Wave of Asthma Therapeutics
- Bearingless flux reversal motor for neonatal and pediatric extracorporeal life support applications