SBIR/STTR Research Award

Addressing Lumbar Puncture Challenges Using Patch Ultrasound and Augmented Reality

Award identifier b4324c071d8056ef9a85203e4e3cf495a0eeb698a20edf1c5674f10a1211e5d7Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$311,922

Program and phase

SBIR · Phase I

Award year

2021

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
CLEAR GUIDE MEDICAL, INC.
Proposal award date
2021-05-01
Contract end date
2022-10-31
UEI
N5DTXVC1ZXA6
Solicitation number
PA20-260
Topic code
NIBIB

Research abstract

PROJECT SUMMARY Every year, neurologists and emergency personnel perform over 400,000 diagnostic and therapeutic lumbar punctures (LP) to collect cerebrospinal fluid (CSF), a vital fluid in the diagnosis and treatment of a myriad of neurological diseases and disorders. Under standard care, LPs are performed in an inpatient environment at the bedside. The procedure involves navigating a needle that can be up to 14 cm in length into a 3-6 mm target window in the lumbar spine region. Physicians face the challenge of precise, accurate navigation and placement of the needle to the target. Failure to collect a viable sample and procedure-related complications can lead to misdiagnoses, treatment delays, and unnecessary and even dangerous procedures. Currently, the average physician takes 3 attempts to correctly place the needle. The associated failure rate of the procedure is ~23.3%. The failure rate rises to 50% in obese and scoliotic patients, for which the physician must navigate through excess adipose tissue and difficult anatomy. Failure to collect CSF leads the use of fluoroscopic guidance, which takes longer and subjects the patient and physician to ionizing radiation. Except for fluoroscopic guidance, the current standard of care does not involve any visualization of tissue using technology such as topical ultrasound. In this phase I application, we propose a navigation system featuring a patient-anchored ultrasound patch which transforms LPs from a blind procedure with high failure rate to a fast and simple one. Our solution addresses the typical shortcomings of regular ultrasound guidance which has limited its wide adoption for LPs. The patch ultrasound relieves the clinician from handling the ultrasound and needle simultaneously, yields high-contrast images of the vertebrae pathway, and provides a reliable 3D volume. The navigation system with augmented reality helps the clinician to successfully reach the target on the first try. Most importantly, the combination of these technologies offers what we call active needle visualization, where the imaging plane of the ultrasound is controlled to provide an optimal view of the needle in a closed-loop system. Our hypothesis in this proposal is that the simplicity of the patch design and the availability of off-the-shelf navigation components combined with Clear Guide’s matured navigation platform promises a cost-effective solution suitable for the clinical application at hand. We will achieve our goal through the following aims: (1) Develop and Integrate Patient-anchored Ultrasound Imaging Patch with Clear Guide Medical Tracking System, (2) Interface Design and Incorporation into a Tablet and head-mounted display (HMD), and (3) Accuracy Measurement and User Data Collection. The ultimate goal of this academic (Johns Hopkins University) and industry (Clear Guide Medical) collaboration is the safe, economic, and effective development of patient-anchored ultrasound patch to actively guide LP procedures.PROJECT NARRATIVE Every year, neurologists and emergency personnel perform over 400,000 diagnostic and therapeutic lumbar punctures to collect cerebrospinal fluid, a vital fluid in the diagnosis and treatment of a myriad of neurological diseases and disorders. The associated failure rate of the procedure is approximately 23% and the failure rate rises to 50% in obese and scoliotic patients. Our goal is to develop a cost-effective patient-anchored ultrasound patch with navigation system, which transforms lumbar punctures from a blind procedure with high failure rate to a fast and simple one.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

13 SBIR/STTR records share this UEI (2011–2022). Reported award amounts total $8,806,105. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Health and Human Services

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.