SBIR/STTR Research Award

Improving Anticoagulation Monitoring in Pediatric Patients: Use of a Microfluidic Platform to Test Low Volume Blood Samples Obtained by Heel-Stick Collection

Award identifier 312a8087048af90a06c22040fcdf5198386b1224ebdf0fa55d098f1396ee9635Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$2,654,326

Program and phase

SBIR · Phase II

Award year

2021

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
BAEBIES, INC.
Proposal award date
2021-05-01
Contract end date
2024-03-31
UEI
NZSZBQ9B84T1
Solicitation number
HL19-017
Topic code
NHLBI

Research abstract

ABSTRACT Improving Anticoagulation Monitoring in Pediatric Patients: Use of a Microfluidic Platform to Test Low VolumeBlood Samples Obtained by Heel-Stick Collection(HL140662 Phase IIB SBIR) Anticoagulation therapy is indicated for children who suffer from congenital heart defects, thrombosis, or who are at risk of developing thrombosis. Over the past decade, there has been a dramatic increase in the use of anticoagulation therapies in pediatric patients, with up to 15% of hospitalized children receiving heparin or heparinoids. The use of these therapies necessitates frequent laboratory testing (every 4 hours) of multiple analytes -- anti-thrombin function (ATIII), Factor Xa activity (Xa), and activated partial thromboplastin time (aPTT) -- to avoid underdosing (thrombotic events) or overdosing (bleeding). Existing diagnostics for heparin therapy are problematic in newborns and children as they are generally standardized for adult samples and require as much as 2 mL of whole blood per analyte or a cumulative blood volume of up to 12 mL per day for the full panel. There is a critical unmet need to develop a low-volume, minimally invasive, and rapid turn-around diagnostic test panel for monitoring heparin therapy in children that features multiple analyte testing on a single platform. Work completed through Phase I and II of this project (R44HL140662) has established feasibility to perform a panel of three critical assays (ATIII, Xa, and aPTT) for laboratory quality monitoring of anticoagulants (heparin, heparinoids) on our near patient digital microfluidic platform (FINDER). This platform was recently CE marked for glucose-6-phosphate dehydrogenase (G6PD) testing and is pending 510(k) clearance from the FDA. The proposed Phase IIB project will support full analytical validation per CLSI guidelines and a rigorous clinical validation necessary to obtain FDA clearance for our heparin assay panel. We are preparing to engage in a pre- submission with the FDA regarding our validation protocols and design of the validation studies to meet 510(k) requirements based on single test predicate devices for each analyte. We are working closely with our clinical partners at Boston Children’s Hospital to optimize the heparin testing platform workflow for seamless integration into a hospital laboratory setting upon commercialization. Funding through this Phase IIB mechanism will complete the developmental path for our FINDER heparin monitoring platform, from concept to market through anticipated FDA clearance. There is currently no single point-of-care testing platform available that supports rapid testing of ATIII, Xa, and aPTT. The small volume format inherent to our digital microfluidic technology enables all three assays to be performed with less than 50 L of whole blood or plasma, collected via heel-stick or venipuncture, and is perfectly suited for use in pediatric settings where frequent blood draws significantly increase the risk of iatrogenic anemia. By combining three technically complex assays into a single, automated platform, we can improve both technical performance of heparin monitoring assays (reduced sample-to-answer time, three analyte test results from a single blood sample) and improve clinical outcomes through reduced blood volume needed for recurrent testing of heparin and other anticoagulants.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

45 SBIR/STTR records share this UEI (2014–2025). Reported award amounts total $42,450,057. Reported amounts are not federal obligations.

Phases: Phase II, Phase I, Phase II – Direct to Phase II

Agencies: Department of Health and Human Services, Department of Defense

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.