SBIR/STTR Research Award
Development of a blood pressure monitoring system based on smart-camera video recording
Award amount
$237,733Program and phase
SBIR · Phase IAward year
2021Award details
- Awarding agency
- Department of Health and Human Services
- Branch
- National Institutes of Health
- Recipient company
- OVID BP SYSTEMS, INC.
- Proposal award date
- 2021-04-15
- Contract end date
- 2022-04-14
- UEI
- CKECT79F1EH3
- Solicitation number
- PA20-260
- Topic code
- NHLBI
Research abstract
PROJECT SUMMARY
Hypertension causes 7.5 M deaths worldwide with no warning signs or symptoms and occurs in more than two
thirds of individuals over the age of 65. Hypertension represents a major risk factor for coronary heart problems
including ischemic and hemorrhagic strokes, kidneys failure, and visual impairment. The most impactful action
against hypertension is represented by frequent blood pressure (BP) measurements, which assure early
intervention and its successful management. BP monitoring occurs mainly at the Health Care Provider’s (HCP)
office through cuff-based devices (e.g. sphygmomanometer) that can only accurately be operated by trained
personnel. Moreover, clinical BP measurement has the potential to cause Masked and White Coat Hypertension,
two well-known phenomena that prevent correct BP assessment and assignment of a proper therapeutic plan in
nearly 40% of the patients. Other alternatives are represented by ambulatory BP monitoring (ABPM) and home
blood pressure measurement (HBPM) devices which have shown limitations due to costs, practicality, and
inaccuracy. Ovid BP proposes an innovative technology to allow comprehensive BP detection and management
via patented software that leverages today’s advanced smartphone camera technology to capture the
biomarkers required to determine a patients’ BP. The solution is empowered by an algorithm that estimates BP
from the heart’s QRS signal, which is specifically captured through analysis of the patients’ Vertical Head
Movement (VHM). Additionally, the rate of facial blood flow is observed through the well-understood practice of
video plethysmography (vPPG). With this data the system is capable of producing the Instantaneous Hearth
Rate Period (THRi) and Instantaneous Pulse Transit Time (PTTi), which are analyzed by a cloud-based algorithm
yielding systolic and diastolic blood pressure as well as heart rate in a matter of moments. Ovid’s technology has
been tested in-vivo against clinical-grade HBPM devices and has exhibited a strong correlation to the reference
measurements obtained by the modern standard. In this Phase I application, Ovid BP will assess the feasibility
of the proposed approach to correctly detect BP when confronted with variables that might affect vPPG and QRS
estimation. Specific activities will include a study on selected human subjects to validate the technology against
a mercury sphygmomanometer and to investigate the role of age, sex, skin tone, and BP baseline as the cause
of errors. Data collected will be used to perform algorithm refinements required to solve any issues associated
with these variables. The conclusion of the proposed Phase I study will establish the feasibility of Ovid BP’s
video-based approach to measuring BP. During Phase II, Ovid will conduct a larger study to identify and solve
other key issues affecting the readings, including potential dermatological conditions that may impede the
accurate assessment of both VHM and PPG.PROJECT NARRATIVE
Hypertension is a “Silent Killer” that affects approximately 30% of the population of the United States and
accounts for 3.7% of the total disability-adjusted life years (DALYS) worldwide. Accurate diagnosis of
hypertension requires frequent Blood Pressure (BP) measurements, which are impractical or unreliable with
traditional methods. Ovid BP Systems has developed the first video-based BP monitoring system requiring only
the camera found in nearly every smartphone, tablet, or PC, allowing constant BP monitoring in support of prompt
diagnosis and intervention against hypertension.
Technology keywords
Not reported
Awards with the same topic code
Verified by an exact topic code match. This is not a text-similarity match.
- DUCTUS ARTERIOSUS STENT TO IMPROVE CONGENITAL HEART DEFECT MORTALITY
- Head Up CPR and Aortic Occlusion to Improve Survival after Refractory Cardiac Arrest
- Free-Breathing Dynamic Cardiopulmonary Function Imaging System to use with Xenon MRI
- The Next Wave of Asthma Therapeutics
- Bearingless flux reversal motor for neonatal and pediatric extracorporeal life support applications