SBIR/STTR Research Award

Reading workstation for clinical contrast echocardiography

Award identifier 3510ca0a8d7fd548bf8f3e2085aeaeca79a52ddd2ac112fc891f6628862e8f63Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$252,399

Program and phase

SBIR · Phase I

Award year

2021

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
Narnar, LLC
Proposal award date
2021-03-01
Contract end date
2022-02-28
UEI
H5UXYYLCY2N6
Solicitation number
PA19-272
Topic code
NHLBI

Research abstract

Proposal Summary There is increasing appreciation of a syndrome in which patients female patients, present with chest pain due to myocardial ischemia and have a normal or near normal coronary angiogram. Termed coronary microvascular dysfunction (MVD) this disorder is not benign with cardiovascular event rates similar to those with established coronary artery disease. Clinical tools are therefore needed to both identify MVD patients and better understand the mechanisms causing myocardial ischemia. There is evidence that myocardial contrast echocardiography (MCE) provides incremental information in the evaluation of patients with coronary artery disease, myocardial viability, or diseases of the microvasculature. Despite data demonstrating the diagnostic and prognostic benefit of MCE in evaluating patients with MVD, its clinical use has been limited to only a handful of experts in the field, because there are currently no widely available clinical tools to support MCE quantitative analysis and interpretation. The overall aim of this Phase I proposal is to provide clinicians with a new tool to evaluate the myocardial flow-function relationship that is critical to identifying patients with MVD by using echocardiography. We will develop clinical software that can rapidly process MCE data into a standardized, quantitative and easy- to- interpret format. In Aim 1, the power of image averaging and computer aided assessment of radial wall thickening will be used to enhance the current standard of care which relies solely on readersandapos; visual estimation of segmental function. An algorithm will be developed to rearrange the order of images so that images representing the same phase of the cardiac cycle are grouped together. Functional analysis will then be developed using computer-aided tracings of epicardial and endocardial borders. In Aim 2, a software module for quantitative analysis of real-time MCE perfusion will be developed that will incorporate statistical confidence, derived from the performance of image processing algorithms to inform the interpreter about the data strength. Machine learning will be utilized to train and deploy a neural network for the pixel-by-pixel assessment of myocardial perfusion. In Aim 3, we will combine myocardial perfusion and function modules into a novel, perfusion-function mode of imaging (PF-mode). This new mode will be applied to an archival sample of clinically diagnosed MVD cases to demonstrate the feasibility to detect abnormalities in the myocardial flow-function relationship. The composite PF-mode will include a cine-loop rendered for one cardiac cycle where parametric images (perfusion) are superimposed over averaged ultrasound images with an overlay of graphic representation of wall thickness (function). This novel mode of imaging provides the means to diagnose MVD in a single clinical study.Project Narrative Project Title: Reading workstation for clinical contrast echocardiography Despite a wealth of evidence that myocardial contrast echocardiography imaging of myocardial perfusion provides incremental information in the evaluation of patients with diseases of the myocardial microvasculature (MVD), its clinical use has been limited to only a handful of experts in the field. In this proposal, we have created a multidisciplinary partnership between physicians-scientists and engineers with the overall aim to address this clinical gap that exists between a proven echocardiographic technique and the technology necessary to enable widespread adoption of MCE clinically. We will develop a software program enabling a new method for evaluating the myocardial flow-function relationship using echocardiography that will enable the identification of MVD using MCE studies at the level of expert readers.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

2 SBIR/STTR records share this UEI (2021–2022). Reported award amounts total $2,227,926. Reported amounts are not federal obligations.

Phases: Phase II, Phase I

Agencies: Department of Health and Human Services

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.