SBIR/STTR Research Award

Biomimetic size-adaptable heart valve for prosthesis-patient mismatch

Award identifier 1818165a52486507aa6c140a0b890eabaceb0d977b950e0ea115d6bc5fb09a6cAwarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$299,994

Program and phase

STTR · Phase I

Award year

2021

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
Autus Valve Technologies, Inc.
Proposal award date
2021-01-01
Contract end date
2021-12-31
UEI
PWZ1GQLDP277
Solicitation number
PA19-270
Topic code
NHLBI

Research abstract

ABSTRACT The overall goal of this Phase I STTR project is to develop a biomimetic size-adjustable prosthetic heart valve (Autus Size-Adaptable Valve) that can be expanded post-implantation to accommodate changes in blood flow due to somatic growth or cardiac remodelling, to prevent the complications of valve prosthesis-patient mismatch (PPM). By design, all existing surgical prosthetic valves have a fixed functional diameter, leaving tens of thousands of patients at risk of developing valve PPM due to changes in body size, or heart remodeling. Growing children who undergo valve replacement develop PPM and currently need repeated invasive open-heart operations to replace outgrown valves. In adults, over 50% of patients who undergo surgical aortic valve replacement develop PPM, leading to higher risk of mortality. The Autus Size- Adaptable Valve is intended for surgical pulmonary or aortic valve replacement and can be expanded post- implantation, via minimally invasive transcatheter balloon dilation. Autus Valve Technologies, Inc. developed the Autus Size-Adaptable Valve as a biomimetic bileaflet prosthetic heart valve that is size-adjustable to prevent PPM. The design mimics the dynamic structure- function relationship of the human venous valve to provide a size-adaptable valve replacement that maintains optimal function across a wide range of dimensions. Benchtop durability testing, computational modeling, acute in vivo studies, and 20-week survival studies in growing lambs validated functional performance and structural integrity of the biomimetic design. The next technical challenge is to optimize the frame geometry and select materials that will minimize the risk of stent failure in preparation for clinical testing in children. The objective of Phase I is to confirm feasibility by completing two design objectives: 1) Optimize the frame geometry to minimize risk of failure at each stage of device expansion and in response to external compression, and 2) Identify the optimal frame material to proceed with design verification testing and a first-in- human clinical study. Therefore, Aim 1 is to optimize the design of the expandable bileaflet valve frame using finite element computational modelling. The frame geometry will be optimized to minimize von Mises stress and plastic strain in the frame at all stages of device expansion. Aim 2 is to perform a failure and fatigue analysis of the optimized expandable bileaflet valve frame and evaluate the mechanical response to expansion and compression to develop a finalized prototype for in vitro validation studies. Safety factors for frame failure and fatigue will be established and the optimal frame material will be identified. The final deliverables will be an advanced prototype that has: 1) an optimized frame design to minimize the risk of failure with expansion and under external compression; 2) established safety factors for frame failure and fatigue at all stages of device expansion; and 3) a frame material suitable for first-in-human clinical use.PROJECT NARRATIVE This project will develop the Autus Size-Adaptable Valve, a biomimetic size-adjustable prosthetic heart valve that can be expanded after implantation to increase blood flow as recipients grow or undergo other changes in heart function. The Autus Valve will eliminate the need for additional invasive surgeries to replace valves that are outgrown or no longer match to current heart function. This technological breakthrough will avoid multiple invasive surgeries, reduce healthcare costs and lifetime risk of morbidity and mortality, and improve patient quality of life.

Technology keywords

Not reported

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.