SBIR/STTR Research Award

Decellularized xenograft leaflet patch for pulmonary valve repair in pediatric patients

Award identifier 2d61e1b5badbe3b542ea3d8dbaa40bc33d86cf09400e872b83c6dd7932fb6306Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$327,779

Program and phase

STTR · Phase I

Award year

2020

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
Annoviant, Inc.
Proposal award date
2020-09-30
Contract end date
2021-09-29
UEI
D9WMZ24BAKL5
Solicitation number
PA19-270
Topic code
NIBIB

Research abstract

Congenital heart disease affects approximately 40,000 newborns each year in the U.S. Valve repairs are needed for pulmonary valve, particularly for patients with the diagnoses of tetralogy of Fallot, tetralogy of Fallot with absent pulmonary valve, tetralogy of Fallot with AV canal, pulmonary valvar stenosis, and pulmonary valvar atresia. An additional group are patients with a prior repair of tetralogy of Fallot and pulmonary valvar regurgitation. This latter group may be the largest, and currently receive bioprosthetic valves in surgically or by catheterization. The longevity of both of these types of pulmonary valve replacements is limited. Leaflet repair materials in current use include autologus pericardium; glutaraldehyde treated bovine pericardium, and polytetrafluorethylene (PTFE). The limitations of these materials involve to varying degrees their thrombogenicity, durability, susceptibility to infection, and lack of growth potential. These materials also have varying degrees of stiffness and flexibility, which present technical challenges for surgeons, particularly in neonates and infants where size constraints and limited space in the mediastinum combine with the relatively thin immature native vascular tissues to create tissue-materials mechanical mismatches, which can compromise the ability to achieve a successful surgical repair. Current clinical experience indicates that young age, in particular, is an important risk factor for shortened intervention free survival in patients requiring these valves as part of their initial surgical repair. The goal of creating a leaflet repair patch that will overcome these limitations has not been achieved. We propose to develop a commercializable leaflet repair patch prototype and test the regenerative potential of decellularized and pentagalloyl glucose (PGG) treated porcine aortic valve leaflet repair patch with attached aortic wall (TxGuard-LP) that would repopulate with host cells and slowly regenerate and grow with the patient without unwanted inflammation and degeneration in contrast to the existing repairing procedures. Our specific aims for STTR Phase I are: Specific Aim 1: Evaluate TxGuard-LP for material properties after sterilization and extended storage such as suture pull out test, biaxial mechanical testing, and enzymatic resistance. We will also test sterility assurance level and rinsing protocols for further implantation. Specific Aim 2: Evaluate TxGuard-LP for biocompatibility. This will include 30, 60, and 90-day subdermal implantation in juvenile rats to assess calcification resistance, inflammatory cellular response and remodeling. Specific Aim 3: Evaluate TxGuard-LP for functional assessment in growing lamb as a pulmonary leaflet replacement patch for three months to assess safety, function, biocompatibility, and cellularization by the host cells in a circulatory environment.Congenital heart disease affects approximately 40,000 newborns each year in the U.S. Valve repairs are needed for malformed pulmonary valve, aortic stenosis (Konno procedure, Ross procedure), double outlet right ventricle (Rastelli operation), extracardiac conduit (Fontan operation), pulmonary valve replacement (Tetralogy of Fallot). Current replacement materials are suboptimal with high failure rate requiring reoperations. This research proposal is designed to develop a new leaflet repair patch for pulmonary and aortic valve repair (TxGuard-LP) that allows ease of suturing, resists early degeneration, and allows regeneration with host cells so that the leaflet would grow with the pediatric patient.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

4 SBIR/STTR records share this UEI (2019–2024). Reported award amounts total $4,656,269. Reported amounts are not federal obligations.

Phases: Phase II, Phase I

Agencies: Department of Health and Human Services

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.