SBIR/STTR Research Award

FVIII Point-of-Care Monitoring Device and App

Award identifier 00eaecabff0bb5dbb82112e2528267a683ef22e4537b4f469526cc7b04d2f493Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$1,473,927

Program and phase

SBIR · Phase II – Direct to Phase II

Award year

2020

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
THE DNA MEDICINE INSTITUTE, INC.
Proposal award date
2020-09-10
Contract end date
2022-05-31
UEI
PUESWMALMKD4
Solicitation number
PA18-574
Topic code
NHLBI

Research abstract

FVIII Point-of-Care Monitoring Device and App Summary/AbstractHemophilia A results from a deficiency of FVIII-activity and can result in severe bleeding. Head bleeds can be debilitating and joint-bleeds require major medical intervention. In this Direct-to-Phase II effort, we will leverage our CE-marked FVIII fluorogenic substrate assay to develop a cost-effective point-of-care (POC) FVIII test for whole venous or capillary blood with a 15-minute turnaround time. Hemophilia A is an X-linked recessive genetic disorder with an incidence of 1 in 5000 live male births. For patients with hemophilia A, lifelong treatment is required to provide adequate and therapeutic FVIII levels. The ability to monitor their FVIII levels is essential to maintaining optimal therapeutic dosing. Individual pharmacokinetics can affect the clearance of recombinant FVIII therapies. Over time, patients can develop inhibitors, which may dramatically change a drug’s effectiveness over time. Given, the complexity of FVIII lab measurements, there are currently no FVIII measurement approaches available at the point-of-care. All approaches to FVIII measurements are reliant on skilled clinical laboratory personnel and specialized laboratory equipment for assay automation, resulting in challenges to standardization, implementation, and access.In preliminary work, we have developed three innovations: (1) a high-sensitivity CE-marked FVIII fluorogenic assay that spans andlt; 1 -200% FVIII levels, (2) a sample-to-answer capable cartridge that performs all sample processing for our assay, and (3) a concept FVIII prototype device and app wireframe. In this proposed work, we plan to leverage our work to advance FVIII monitoring work via three aims: (1) Demonstrate a CLIA-waivable sample-to-answer consumable, (2) Assess our FVIII monitoring device, app, and consumable performance over 1-200 FVIII% levels, with interfering substances, and on capillary blood, (3) Assess FVIII monitoring device at Boston Children’s Hospital (N=45) on hemophilia patients, study human factors and precision. During the effort, we will work closely with hemophilia experts, including the World Federation of Hemophilia, to ensure we have an approach for all patients worldwide.The success of developing a FVIII POC diagnostic will allow patients and providers a precision medicine approach to managing their disease. Home use will allow for more frequent measurement of FVIII levels to ensure therapeutics levels prior to engaging in physical activity and to assess correct dosage administration, including potential missed doses. It will allow newer therapies, including extended half-life PEGylated FVIII and gene therapies, to be monitored. The approach can be utilized to create FVIII activity trends which can be translated into pK data to assess changes over time, which may alert care providers to test for inhibitors. The results of our efforts will be a human-centered FVIII Bluetooth-connected monitoring device, consumable, and app that will provide accurate and easy FVIII monitoring with the goals of decreasing risk of unexpected bleeding and increasing patient care in all settings.Project Narrative Hemophilia A results from a deficiency of FVIII-activity and can result in severe bleeding. Head bleeds can be debilitating and joint-bleeds require major medical intervention. The results of our efforts will be a human- centered FVIII Bluetooth-connected monitoring device, consumable, and app that will provide accurate and easy FVIII monitoring with the goals of decreasing risk of unexpected bleeding and increasing patient care in all settings.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

13 SBIR/STTR records share this UEI (2005–2024). Reported award amounts total $12,120,097. Reported amounts are not federal obligations.

Phases: Phase II, Phase I, Phase II – Direct to Phase II

Agencies: National Aeronautics and Space Administration, Department of Health and Human Services

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.