SBIR/STTR Research Award

Development of a Partial Occlusion Device to Aid in Coring and Anastomsis of the Aorta

Award identifier 8c91e058b77373d185f05aac54b463559bec25d9599724f90e87ce1bf85436d4Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$278,487

Program and phase

SBIR · Phase I

Award year

2020

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
Myocardial Assist Systems & Technology LLC
Proposal award date
2020-08-21
Contract end date
2021-08-20
UEI
FM8XH18NYPC7
Solicitation number
PA19-272
Topic code
NHLBI

Research abstract

Heart failure (HF) accounts for 1 in 4 deaths in the US each year, making it the leading cause of death with a HF patient population of over 6.5 million people. Due to a scarcity of donor hearts, left ventricular assist devices (LVADs) have gained clinical acceptance as an alternative treatment option to heart transplantation due to their durability and long-term viability. Improved survival and reduced mortality have been associated with less invasive and off-pump approaches. Current clinically-approved LVADs require aortic partial clamping to facilitate outflow graft anastomosis and may also require cross-clamping of the aorta and cardiopulmonary bypass (CPB) during LVAD implantation. To improve clinical outcomes, MAST LLC (Louisville, KY) is developing a two-balloon partial occlusion device (CardiAction) designed to provide a safe, reliable, and effective hemostatic field that allows for the anastomosis of an LVAD outflow graft without the need for external clamping. The CardiAction system internally occludes the ascending aorta (clamping), creating a hemostatic pocket for which an anastomosis can be placed, while still allowing vessel perfusion (up to 5 L/min flow, andlt; 5 mmHg) without vessel tissue damage. CardiAction is a catheter-based system comprised of a balloon-stent structure, multi-lumen conduit, and a delivery sheath. The balloon-stent structure, which consists of two polyurethane, toroidal balloons positioned on the ends of a woven-polyester covered self-expanding and collapsible stent, will provide aortic occlusion enabling the perfusion through the device lumen. The balloons are inflated until sufficient vessel wall contact is achieved, creating a static environment between the balloons. The multi-lumen conduit and delivery sheath will assist in device placement, deployment, and retraction. The proposed tool will be a less invasive 18Fr sheath catheter-based solution. The stent cover provides a central lumen for perfusion, eliminating risks associated with complete vessel occlusion. The inflated balloons provide intravascular occlusion that maintains the natural vascular structure, thereby creating a static environment that will provide the surgeon with a leak-free area to operate on the vessel while also reducing the potential for tissue damage. In this SBIR phase I proposal, we will demonstrate feasibility of the CardiAction system, and then plan to submit a phase II proposal to complete engineering development to achieve a design freeze of the CardiAction system and complete pre-clinical testing to demonstrate efficacy, safety, and reliability. The phase II experimental data will be used to support an Investigational Device Exemption (IDE) application to the Food and Drug Administration (FDA) for clinical trials.Investigators at MAST LLC (Louisville, KY) and the University of Louisville (Louisville, KY) are developing a balloon partial occlusion device, CardiAction, to facilitate minimally-invasive surgery for implant of mechanical circulatory support (MCS) device outflow grafts. The CardiAction system will enable surgeons to connect the MCS device outflow graft to the aorta without the need for external partial clamping of the aorta or CPB support, which should result in shorter procedures with improved patient outcomes and better quality of life.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

2 SBIR/STTR records share this UEI (2018–2020). Reported award amounts total $582,304. Reported amounts are not federal obligations.

Phases: Phase I

Agencies: Department of Health and Human Services

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.