SBIR/STTR Research Award

A Non-Contact Optical Patient and Beam Dosimetry System for Continuous in vivo Radiotherapy Verification

Award identifier 709fd5f5c335eb13397f8a9f76c1c2aa91fcabde1076fad6980b37dc68dbf673Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$2,000,000

Program and phase

SBIR · Phase II

Award year

2019

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
DOSEOPTICS LLC
Proposal award date
2019-06-01
Contract end date
2021-05-31
UEI
QERKPUEMGKH3
Solicitation number
PA17-302
Topic code
102

Research abstract

Abstract Optical Cherenkov video imaging of body anatomy and dose delivery can be used now to map out radiotherapy beam incidence upon the patient tissue, directly visualizing the radiation dose deposition on the patient in real time. This could serve as a non-contact workflow tool for verification for daily fractionated radiation therapy, allowing capture of all treatments, all the time. DoseOptics has developed the C-Dose™ camera system, capable of real-time imaging, used in on-going clinical studies in radiation oncology at the Dartmouth-Hitchcock Medical Center. The live 2-D images of the radiation beam on the surface of the patientandapos;s tissue, will be integrated with real-time optical surface mapping of patient anatomy from surface mapping. To achieve our goals, the mapping system needs specialized gating off during each radiotherapy pulse-on time, allowing Cherenkov image capture at 360 Hz, the pulse rate of the linac. Additionally, to make the C-Dose images quantitatively accurate, a correction for tissue emissivity needs to be added in, and active imaging from the mapping projector and C-Dose camera will provide this. The combined system should have better than 3% accuracy in calibrated Dose linearity, and the combined overlay on the patient anatomy will make the system the most functional yet for beam and patient position dosimetry. This will be all verified in the Phase 1, and then the combined system will be developed for a multicenter trial, testing for the rate of observed incidents in whole breast radiotherapy. The RO- ILS data based indicates that 27% of incidents are discovered during therapy delivery, and so we will test the systems in two centers where the patient alignment practice is different (laser andamp; tattoo alignment, vs optical alignment) and track incidents related to accuracy of beam and body position. In the completion of this work, we will have a completed system ready for regulatory clearance, and have the data required to demonstrate value to the customers, being the radiotherapy team and the patients getting their daily treatment. This project is backed by a considerable amount of prior camera development and a critical commercial/marketing partner, and will produce the worlds first all optical, non-contact imaging dosimetry system. The team members involved have expertise in all aspects of the development and clinical radiotherapy physics needed to make the project succeed. Beyond this specific application of whole breast radiotherapy, there are other key applications in which the system could be useful as well, where the field sizes are large and dynamics and patient positioning are critical.Live optical imaging of body anatomy and dose delivery can be achieved with a new product, TrackRT, which uses body surface scanning and Cherenkov imaging combined together for the first time. This product will be designed, developed and tested for FDA approval, such that it can be commercialized, for deployment in radiation therapy centers.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

13 SBIR/STTR records share this UEI (2015–2025). Reported award amounts total $14,999,062. Reported amounts are not federal obligations.

Phases: Phase I, Phase II, Phase II – Direct to Phase II

Agencies: Department of Health and Human Services

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.