SBIR/STTR Research Award

Improved Esophageal Safety in Atrial Fibrillation Elimination

Award identifier 3351ec3b10281ea472223c73d35297d374ed15fbcbad592ec70a6ffc73c4ff2cAwarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$1,189,793

Program and phase

SBIR · Phase II

Award year

2019

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
Biotex, Inc.
Proposal award date
2019-05-15
Contract end date
2021-04-30
UEI
SUH7H6LEZTS2
Solicitation number
PA17-302
Topic code
NHLBI

Research abstract

The overall goal of this SBIR proposal is to develop a novel device to allow easier atrial fibrillation (AF) ablation procedures by mitigating risks for esophageal injury. Atrial fibrillation is the most common chronic disease of heart rhythm, and can be treated with application of radiofrequency energy or cryo to ablate susceptible portions of the endocardial surface of the pulmonary veins through the left atrium. Complications of this procedure include injury to the esophagus, which lies immediately posterior to the thin walled left atrium. Injury can range from asymptomatic ulcerations in the esophageal lumen, to rare, but catastrophic atrioesophageal fistula (AEF) with subsequent stroke and death. Currently, methods to avoid these complications include avoiding ablation within 1cm of the esophagus, and esophageal temperature monitoring. However, most patients’ anatomy precludes avoiding ablation within one centimeter of the esophagus. Temperature monitoring and avoiding exceeding a certain temperature threshold can prolong the procedure and decreases procedural success rates. In fact a significant high rate of procedures must be aborted because the position of the esophagus relative to the ablation site creates unacceptably high risk for injury. In our physician collaborator’s practice in 2016, 19% (41 of 218) of pulmonary vein isolation procedures had incomplete isolation of at least one vein due to proximity of the esophagus. It’s clear that current techniques to protect the esophagus during ablation procedures are rudimentary, and no purpose-built device has received FDA approval for this indication. BioTex has licensed from the Texas Heart Institute and Baylor College of Medicine to create the first ever device designed for controlled deformation of the esophagus away from the left atrium and pulmonary veins as well as enhanced temperature monitoring to improve the safety and efficacy of atrial fibrillation ablation procedures. The objective of this Fast Track proposal is to build fully functional prototypes, conduct benchtop testing, perform pilot animal studies demonstrating reduction of the rate of esophageal injury during radiofrequency ablation, complete a final design of the device, complete all required validations, and obtain regulatory marketing clearances. We anticipate this novel approach will be an easy replacement for existing esophageal temperature monitoring methods, and have a significant impact on patient safety and allow significant improvements in procedure efficiency and health care cost savings.This proposal aims to develop a fully functional esophageal protection device to temporarily deform the shape of the esophagus and monitor luminal temperature during atrial fibrillation ablation procedures. This project proposes to bring together expertise in medical device development with clinical collaborators to develop a novel device for protecting the esophagus during atrial fibrillation ablation procedures and solve an important problem for all cardiologist performing such procedures. The developed technology is expected to have a significant impact on patient safety, procedure time, and likely resulting efficacy by allowing more effective ablation of areas that might otherwise be too close to the esophagus to treat adequately.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

60 SBIR/STTR records share this UEI (1997–2025). Reported award amounts total $24,544,336. Reported amounts are not federal obligations.

Phases: Phase I, Phase II, Phase II – Direct to Phase II

Agencies: Department of Health and Human Services, Environmental Protection Agency, Department of Defense, National Science Foundation, Department of Agriculture, National Aeronautics and Space Administration

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.