SBIR/STTR Research Award
High Energy Micron Scale Pixel Hybrid Detector
Award amount
$150,000Program and phase
SBIR · Phase IAward year
2019Award details
- Awarding agency
- Department of Energy
- Branch
- Not reported
- Recipient company
- Farrier Microengineering LLC
- Proposal award date
- 2019-02-19
- Contract end date
- 2019-11-18
- UEI
- RY4YCTFED6N1
- Solicitation number
- DE-FOA-0001940
- Topic code
- 14a
Research abstract
Currently available X-ray imaging detector products are limited in resolution, quantum efficiency, and dynamic range, particularly for X-ray energies above 30KeV. The current performance limitations inhibit progress in understanding complex nanoscale structures in materials through diffraction and tomographic imaging techniques. A new, high resolution, direct X-ray detection image sensor will be evaluated to demonstrate efficacy in addressing the inadequacy of current X-ray image sensor technology at high energy X-ray energies. An area detector, comprised of an amorphous Selenium on CMOS readout array, with micron scale pixel pitch, plus electronics , mechanical enclosure, and software will be evaluated in coherent diffraction and micro-CT imaging test systems. Two complete X-ray imaging cameras will be built and transported to the Argonne National Laboratory and testing will be conducted with the support of the Detector Group of the APS beam line 1-BM. Fundamental parameters such as quantum efficiency, MTF, noise, dynamic range, and image lag will be quantified and performance of the a-Se CMOS detector will be compared with that of existing detectors in the same test apparatus. An important commercial benefit of the micron scale hybrid X-ray detector technology is: When scaled to larger areas and integrated into benchtop micro-CT systems, high resolution 3D X-ray imaging analysis of biological, industrial, and experimental materials will be enabled. Micron scale pixel spacing enables geometric phase information to be captured enabling phase contrast enhancement using non-coherent X-ray sources. Extremely high resolution of 3-D scanned objects is possible at low X-ray flux, with reduced throughput times due to increased quantum efficiency and low noise.
Technology keywords
Not reported
Awards with the same topic code
Verified by an exact topic code match. This is not a text-similarity match.
- Large-Area Atomic Layer Deposition (ALD) of Titanium Nitride for RF Windows
- High-Power RF Window for Pulsed RF Accelerating Cavities
- High Power RF Windows with Improved Multipactor Coating
- MULTI-MEGAWATT RF VACUUM WINDOW FOR HIGH DUTY-FACTOR RF ACCELERATING CAVITIES
- Micron-scale Direct-detection X-ray Detectors