SBIR/STTR Research Award

Miniature Oriented Tri-Axial Fluxgate Magnetometer Sensor

Award identifier ef6f1796c7333a72c7f8124ba68fc89ac99291850b3901c9e0c0fa5f25f4732cAwarding agency Department of Defense · Navy

Award amount

$125,000

Program and phase

SBIR · Phase I

Award year

2017

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Defense
Branch
Navy
Recipient company
WINCHESTER TECHNOLOGIES LLC
Proposal award date
2017-08-30
Contract end date
2018-03-08
UEI
LKL7LFPJK3Q6
Solicitation number
2017.2
Topic code
N172-116

Research abstract

Recent development of unmanned vehicles (UVs) demands for new technologies on tri-axial fluxgate magnetometers with ultra-low noise level, reduced size and weight. The sensitivity and noise level of traditional tri-axial fluxgate magnetometers are limited by the intrinsic noise of magnetic materials. And their size and weight are limited by their bulky magnetic cores. The objective of this proposal is to develop tri-axial fluxgate magnetometers using single-crystal Yttrium Iron Garnet (YIG) films to reach an ultra-low magnetic noise of ~10fT/Hz1/2 , which is ~3 orders of magnitude better than the state of the art tri-axial fluxgate products. This outstanding performance of our proposed fluxgate magnetometers will be achieved by several innovations in this project: (a) development of low-noise magnetic material YIG, (b) design and fabrication of the YIG film with quasi-elliptic edge profile, and (c) rotational excitation mode. The electronic circuits integrated on one board will drive the rotating magnetic field at the frequency of 1650-1700 Hz, detect the single with digitization bit depth of 24 bits, control the measurement, and communicate with UVs. The weight and dimension of the package will be much better than the specifications in the project topic of 2.0lbs. and 8.0in respectively. The compact fluxgate magnetometer.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

19 SBIR/STTR records share this UEI (2011–2023). Reported award amounts total $8,003,214. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Defense, National Science Foundation

Agency intelligence

Department of Defense

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.