SBIR/STTR Research Award

Small Diameter, High Output, Durable Transapical LVAD

Award identifier bf0059c92a67007a8c8e6c1f3fa883f9097a1b704e728d14ffc7533838a3446fAwarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$224,826

Program and phase

SBIR · Phase I

Award year

2016

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
Perfusion Solutions, Inc.
Proposal award date
2016-04-01
Contract end date
2018-11-30
UEI
TF8CUC65VLG5
Solicitation number
PA14-071
Topic code
NHLBI

Research abstract

DESCRIPTION provided by applicant Ventricular assist devices VADandapos s clearly have a role in cardiac medicine how to precisely define that role is still subject to research and debate considering the possibilities of destination therapy bridge to transplant bridge to recovery bridge to definitive therapy and possibly other variants one might specify Certain VAD features are emerging as required sufficient output to truly make a difference to the patient reliability through the period of use however long that might turn out to be after support is instituted ease of use and minimal morbidities associated with use Major medical problems associated with VAD employment have included infection bleeding and thromboembolic events Cardiopulmonary bypass significant incisions to implant VADandapos s and extensive tissue organ displacement further weaken already very ill patients provide pathways for bacterial and fungal ingress and result in adhesions impeding later surgeries Serous fluid filled pockets around pumps are bacterial breeding grounds and extensive foreign body surfaces are opportunities for adhesive antibiotic resisting bacterial colonies to form Shear stresses can shorten red cell life and disturb both platelet and leukocyte function Thrombosis on the foreign surfaces of the pump can form and later embolize and or systemic coagulation pathologies occur Aggressive pump anticoagulation protocols limit a clinicianandapos s ability to respond to other patient issues Perfusion Solutions Inc PSI technology addresses these issues Utilizing passive magnetic bearings durability over years has been demonstrated Flows of LPM at significant pressure differential are possible These bearings enable much larger lower shear gaps than hydrodynamic bearings and an earlier prototype of this technology using the same motor and bearings demonstrated low bench hemolysis and baseline free hemoglobin in day lamb implants Based on the discussions of clinical needs and the characteristics of the PSI technology with thought leaders in the mechanical circulatory support field we will next develop this for minimally invasive transapical implant This concept is not new but our pump holds particular virtues for this implementation A polymer outflow sleeve will carry flow through the aortic valve There are two feasibility issues during phase I Does the apical pump prototype have hydraulic and hemolysis performance matching the characteristics of the existing PSI prototypes and Will two day calf implants match the bench hydraulic characteristics show hematology and biochemistry results in the normal range have no thromboembolic events and at autopsy show no short term significant damage to the valve leaflets the papillary muscles the chordae or other cardiac structures The performance to be matched will be described During phase II new pump prototypes will be built and used for and day studies extending the in vivo demonstration beyond the phase I data while the Phase I pumps will join other PSI pump prototypes on long term endurance testing PUBLIC HEALTH RELEVANCE Heart disease is a major source of mortality loss of quality of life and high medical costs for treatment Blood pumps have shown a potential to not only save lives but to rehabilitate patients to a much higher level of function However present technology still has a significant number of limitations which cause death and disability and high hospitalization costs as a result of the pump implant the proposed project addresses some of these limitations

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

8 SBIR/STTR records share this UEI (2009–2025). Reported award amounts total $1,912,540. Reported amounts are not federal obligations.

Phases: Phase I

Agencies: Department of Health and Human Services

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.