SBIR/STTR Research Award

Implantable Ventricular Assist Device Directed to Long Term Right Side Support

Award identifier e86adcf14315626f4eec6b08597873116eb2f6033ea48fdb60c259d914982888Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$224,915

Program and phase

SBIR · Phase I

Award year

2015

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
Perfusion Solutions, Inc.
Proposal award date
2015-04-15
Contract end date
2016-12-14
UEI
TF8CUC65VLG5
Solicitation number
PA14-071
Topic code
NHLBI

Research abstract

DESCRIPTION provided by applicant LVAD use is increasing for both bridge and destination applications but the need for right ventricular assist is apparent even in patients selected to avoid this complication These patients usually receive a temporary right ventricular assist device RVAD with a short lived external pump when the need becomes apparent although the survival rate is superior with a pre operatively planned biventricular implant The difficulty is a paucity of good implantable systems for RVAD use Existing implantable LVAD pumps adapted to this use bring with them significant compromises for right sided use Perfusion Solutions has developed a passive magnetic bearing pump the andquot M Fandquot that has been demonstrated in multiple sizes The most extensively developed mm pump is well suited as an implanted long term RVAD It is very small but produces strong flow and pressure for the pulmonary circulation The magnetic bearing is not speed sensitive so the pump can be set to slow speed if the ventricle recovers but remain functional if there is a renewed issue with pulmonary resistance or ventricular function The geometry is compatible with flexible implant approaches per individual case constraints Hemolysis is extraordinarily low perhaps due to the large low shear magnetic bearing clearances The pump has shown multi year durability The innovation of this project is the provision of the first clinical implantable RVAD which does not require major compromises to adapt to the application The technical issues with respect to conversion of the M F LVAD for RVAD applications are not challenging The feasibility issue is biocompatibility as an RVAD implant Initial feasibility will be demonstrated by two calf implants without thrombus issues The specific aims for phase I are design of anatomically compatible and biocompatible RVAD inflow and outflow cannulae fabrication of two M F RVAD pumps bench performance and hemolysis testing and two day in vivo RVAD implants During Phase II we will build more systems The database of bench testing will be increased Longer duration implants will be performed as BiVADandapos s combining the PSI system with a commercially available LVAD as appropriate at the time of the phase II proposal and award This will demonstrate a first clinically usable product superior to anything now available or becoming available in the near future and lead into development of a fully integrated BiVAD system utilizing the clinical experience PSI is a Cleveland Clinic spin off company In this project it is teamed with the Clinicandapos s Kaufman Heart Failure Center and Cardiovascular Dynamics Laboratory to meet the pressing need for a satisfactory RVAD system PUBLIC HEALTH RELEVANCE Left ventricular assist devices LVADs have proven to be a lifesaving treatment for end stage heart failure However many patients are excluded from this treatment because of obviously inadequate right ventricular function while some LVAD recipients die or have poor quality of life because their right side function proves to be poorer than expected Today only temporary right side assist pumps are available which is inadequate for large number as of patients This project will demonstrate a small and effective long term implantable pump more suitable for right side use than any technology on the horizon for these patients

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

8 SBIR/STTR records share this UEI (2009–2025). Reported award amounts total $1,912,540. Reported amounts are not federal obligations.

Phases: Phase I

Agencies: Department of Health and Human Services

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.