SBIR/STTR Research Award

POINT-OF-CARE HEMOSTASIS ANALYZER FOR THE INTEGRATED ASSESSMENT OF PLATELET AND COAGULATION FUNCTIONS

Award identifier a5730e36ba6d872c50abc3df8bd5ac8680eba42988717dcc038d6979ba303a2fAwarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$223,394

Program and phase

SBIR · Phase I

Award year

2015

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
Thrombodyne Inc
Proposal award date
2015-09-01
Contract end date
2016-03-31
UEI
RMCNNVCMSXB1
Solicitation number
HL14-011
Topic code
NHLBI

Research abstract

DESCRIPTION provided by applicant The timely diagnosis and optimal management of hemostatic dysfunction in trauma and surgical patients is challenging due to the unavailability of suitable analytical tools The current need to conduct multiple tests with multiple blood samples on multiple devices to ascertain the specific nature of the hemostatic defect by examining the different platelet aggregation and coagulation pathways is time consuming and cumbersome Constrained by the time critical nature of treating a bleeding patient clinicians are often forced to use unguided generic transfusion algorithms that may be sub optimal for some patients An on site hemostasis analyzer that rapidly provides a broadly instructive report on multiple platelet and coagulation functions on a unified platform from a single blood sample on a single cartridge tested on a single device at the point of care has the potential to shift the guided blood product transfusion paradigm To address this compelling need the applicants have developed a hemostasis analyzer with a multichamber cartridge that can simultaneously assess multiple platelet aggregation and coagulation pathways from a single blood sample in less than minutes This cartridge interfaces with a base unit containing optoelectronic modules to detect and quantify platelet aggregation and clotting times in whole blood The data from the instrument can be integrated into the patientandapos s electronic health record that can be accessed by different clinicians to track the patientandapos s hemostatic recovery trend The goal of the proposed feasibility studies is to demonstrate that the novel hemostasis analyzer can reliably and reproducibly assess the status of platelet and coagulation functions in normal and hemostatically deficient blood Platelet aggregation induced by adenosine di phosphate ADP Collagen and Arachidonic acid and coagulation assessed by prothrombin time activated partial thromboplastin time and thrombin time will be measured in a chamber cartridge Sensitivity of the analyzer to coagulopathy will be tested by using clotting factor deficient blood in vitro and by testing blood from patients taking warfarin Sensitivity of the analyzer to platele dysfunction will be tested by using blood from patients taking aspirin and ADP receptor blockers e g clopidogrel Platelet function and clotting times of blood from trauma patients before and after restoration of hemostatic function will also be tested For comparison platelet aggregation and clotting times will be tested using conventional clotting time analyzers and platelet aggregometers The expected outcome of this proof of concept phase of the project is the demonstration that multifactorial hemostatic function and deficiencies in specific hemostasis pathways can be rapidly assessed in the novel single platform system paving the way for commercial development of a hemostasis analyzer that will facilitate guided transfusion of blood products to trauma and surgical patients PUBLIC HEALTH RELEVANCE Blood clotting and bleeding problems are significant healthcare challenges The diagnosis and management of such problems is particularly difficult in surgical and traumatic injury patients Testing the function of platelets a blood cell that plas an important role in blood clotting and coagulation mediated by proteins in the blood in such patients is required to optimize transfusion of blood products such as plasma and platelet packs However current tests are cumbersome and time consuming to perform This project aims to demonstrate the feasibility of a novel system to test a broad range of platelet and coagulation functions rapidly at the point of care with a single sample of blood tested on a single cartridge f this feasibility study is successful a new technology will be developed to significantly facilitat the diagnosis and management of bleeding and blood clotting problems in a wide range of patients including surgical and trauma patients

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

9 SBIR/STTR records share this UEI (2000–2020). Reported award amounts total $7,244,075. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Health and Human Services

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.