SBIR/STTR Research Award

(NCI) Developing an Intermediate Energy Linac for Robotic Radiotherapy

Award identifier e1b546245a3afb4270498fbae5a6a11a8bf8723cf4f1cc6da893d058901bbfcfAwarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$264,741

Program and phase

SBIR · Phase I

Award year

2015

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
RADIABEAM TECHNOLOGIES, LLC
Proposal award date
2015-04-01
Contract end date
2016-08-31
UEI
Q6NDLV47NBT5
Solicitation number
PA16-019
Topic code
NCI

Research abstract

DESCRIPTION provided by applicant Robotic radiotherapy using extensively non coplanar beams has been shown effective to significantly improve radiation therapy dosimetry that leads to improved treatment outcome However current implementation of this technique by CyberKnife is inefficient and not optimal dosimetrically This has severely limited both the number of patients eligible for robotic radiotherapy and the achievable clinical outcome for those who have been treated In order to overcome these limitations we propose to develop a novel robotic radiotherapy system that can efficiently utilize the full potential of the non coplanar delivery space to treat the majority of radiotherapy patients Innovation The proposed system is highly innovative in the following aspect Integrated beam orientation and fluence optimization Significantly more compact linac to allow posterior beams Flexible field sizes and MLC resolution to efficiently treat most target sizes Integrated volumetric imaging system This project is proposed to design a hardware platform materializing such robotic radiotherapy system In order to reduce the gantry size both the linac length and the distance between the source and the MLC need to be significantly reduced We propose to design a new MV source to reduce linac length and provide the required dose rate for treatment The physical MLC leaf thickness cannot be substantially thinner than mm To achieve a high MLC resolution at the treatment distance a spacer is used in CyberKnife between the primary collimator and the MLC increasing the gantry dimension We propose to eliminate the spacer but vary the focus to tumor distances FTD to achieve desired field size and MLC resolution This requires optimization in an enormous solution space a capacity uniquely demonstrated by the p algorithm Volumetric imaging has been an indispensable component of modern radiotherapy but unfortunately missing from existing robotic systems The proposed new linac will be able to deliver kV imaging beams from the same MV linac which in combination with gantry or couch mounted imagers will allow volumetric imaging for more precise tumor targeting Aims Prototypical design of the accelerator to produce MV X rays Design incorporated imaging system Develop a conceptual design for the entire clinical system Impact Success of the Phase I project would lead to the design of the first MV linear accelerator capable of producing a competitively high dose rate of andgt cGy min at cm and kV imaging beams for image guided radiotherapy This paves the technical path to a new robotic radiotherapy system delivering radiation plans with dose conformality surpassing existing X ray platforms More importantly the significantly increased field size throughput and the volumetric imaging capacity would allow the new robotic system to compete for a much larger market including that for conventional linacs than the niche market CyberKnife currently commands PUBLIC HEALTH RELEVANCE Success of the proposed project would lead to the development of a novel radiation therapy device capable of significantly reducing the radiation dose deposited to healthy tissue during cancer treatment The final clinical system to be developed in Phase II would revolutionize the field of radiation therapy by allowing this precise tumor targeting to be achieved with a quick flexible robotic system enabling high patient throughput This system is expected to manage a wide range of diseases and treatment fractions thus having a broad clinical and commercial impact

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

190 SBIR/STTR records share this UEI (2004–2025). Reported award amounts total $96,783,846. Reported amounts are not federal obligations.

Phases: Phase I, Phase II, Phase II – Direct to Phase II

Agencies: Department of Energy, Department of Defense, Department of Homeland Security, National Science Foundation, Department of Health and Human Services, Department of Commerce

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.