SBIR/STTR Research Award

Development of a Field-Deployable Device to Rapidly Measure Blood Cyanide Levels

Award identifier 21c5a22026f1dabe2db4c0a111b2b0bc71510800ae700ef2e6897db077916630Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$1,521,057

Program and phase

SBIR · Phase II

Award year

2014

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
DIAGNOSTIC CONSULTING NETWORK, LLC
Proposal award date
2014-08-01
Contract end date
2016-07-31
UEI
HDHMAZK2SZV4
Solicitation number
PA13-234
Topic code
101

Research abstract

DESCRIPTION The objective of this proposal is to complete the development of a field deployable fully integrated device for the rapid and early diagnosis of cyanide poisoning in whole blood The specific spectral shift of the vitamin B precursor cobinamide after binding cyanide will be used to measure the amount of cyanide in the sample Cyanide is an extremely potent and rapid acting poison with as little as mg fatal to humans Currently there are no portable rapid tests for the detection of cyanide in whole blood available However emergency personnel and first responders have a need to measure the levels of cyanide in whole blood quickly on site in order to treat exposed individuals with an antidote and our test is intended to fill that niche During feasibility we demonstrated that we can detect low levels of cyanide in whole blood from rabbits with our concept device We integrated the cobinamide chemistry into this prototype device by immobilizing modified cobinamide cobinamide polymer on a membrane To achieve that we had to develop a chemical modification through which the cobinamide retains its characteristic spectral shift when binding cyanide after it has been linked to a polymer In our prototype device whole blood was lysed and then passed through the immobilized cobinamide polymer followed by a wash step The spectral shift of cobinamide upon binding cyanide was measured with a handheld spectrophotometer We now propose to complete the development of this prototype device into a fully functional and integrated test device First we will finalize all the assay components and optimize the chemistry for the test in order to maximize the analytical sensitivity In parallel we will be developing a sample collection module that will enable us to reproducibly collect a measured amount of whole blood lyse the red cells and deliver the sample to the test device Once the device and the sample module have reached the prototype stage we are initiating the development of a portable instrument which can interpret the test and provide the user with a concentration of cyanide in the sample The prototype devices will be calibrated and then evaluated with samples from cyanide exposed rabbits and pigs animal models that have documented success and have been accepted by the scientific and regulatory community Production devices sample collection modules and instruments will finally be extensively tested and validated Validation studies for this Phase wil include the confirmation of sensitivity specificity accuracy precision and reproducibility and other studies that are typically required for FDA clearance Clinical studies including pivotal animal studies are outside the scope of this project and will be initiated upon completion of this Phase PUBLIC HEALTH RELEVANCE Cyanide poisoning has been recognized as a threat from smoke inhalation and potentially through weapons of mass destruction but there are currently no point of care methods available to rapidly detect cyanide in blood from at risk patients The objective of the proposed work is to complete the development of a field deployable fully integrated test device for the rapid and early detection and diagnosis of cyanide poisoning in whole blood using the spectral shift of the vitamin B precursor cobinamide upon binding with cyanide as a color indicator Successful completion of this project will lead to the commercialization of the test device which will provide first responders and healthcare professionals with a diagnostic tool and allow them to treat victims of cyanide poisoning quickly and effectively with an antidote

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

3 SBIR/STTR records share this UEI (2011–2019). Reported award amounts total $4,239,251. Reported amounts are not federal obligations.

Phases: Phase II, Phase I

Agencies: Department of Health and Human Services

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.