SBIR/STTR Research Award

Development of a Field-Deployable Device to Rapidly Measure Blood Cyanide Levels

Award identifier 861c64989faa2f2b4821cac14b586a4d18e5011a91a237233d27f2a7b36d3349Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$2,431,111

Program and phase

SBIR · Phase II

Award year

2019

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
DIAGNOSTIC CONSULTING NETWORK, LLC
Proposal award date
2019-09-01
Contract end date
2021-05-31
UEI
HDHMAZK2SZV4
Solicitation number
PAR17-480
Topic code
NINDS

Research abstract

PROJECT SUMMARY The objective of this proposal is to complete the development and verify the performance of a field-deployable, fully integrated sensor for the rapid and early diagnosis of cyanide poisoning in whole blood. Cyanide is an extremely potent and rapid acting poison. It can be inhaled or absorbed across the skin as cyanide gas or ingested as cyanide salt, and has multiple mechanisms of toxicity. Smoke inhalation containing cyanide is one of the main causes of cyanide related casualties in residential fires. Antidotes to cyanide poisoning are currently available, although at a high price. While new and more effective therapeutic agents are in development, there is no rapid diagnostic test to support emergency personnel and first responders who have a need to measure cyanide levels in whole blood quickly in order to safely and effectively treat exposed individuals. Our test is intended to fill that niche. We propose to complete the development of our prototype sensor into a fully functional and integrated test device and to verify its performance. We have established and proven the chemistry and functionality of the chemical sensor and we have integrated the sensor into a microfluidic cartridge that collects a measured amount of blood from a finger-stick, contains all the reagents and buffers, and houses the cyanide sensor. In our prototype microfluidic cartridge a fixed amount of a whole blood sample is collected, the red blood cells are lysed, then passed through the sensor, followed by a manually actuated wash step. In this phase we will first complete the integration of the cyanide sensor and lysis/wash buffer reagents into the microfluidic cartridge after making improvements to and optimizing the cartridge to resolve remaining performance challenges. Testing to qualify and verify the disposable will be done initially with our prototype benchtop reader. In parallel, our main efforts will focus on the hand-held reader development. After a concept stage, alpha versions of the field-deployable instrument will be developed and tested with the cartridge to confirm functionality and to identify areas for improvement. In addition, alpha readers will be evaluated in a usability study with intended users, firefighters and EMT’s, to evaluate their performance and obtain feedback to improve the design and functionality of the system. Hardware and software development of our reader are then scheduled to progress to a pre-production stage and undergo extensive complete system testing prior to the end of this project. The preproduction system performance, disposable and instrument, will be thoroughly evaluated with samples from cyanide exposed rabbits and pigs, as animal models, and spiked human blood. Verification studies for this Phase will include the confirmation of sensitivity/specificity (≥95%), limit of detection (≤20 µM), dynamic range (20-150 µM), accuracy/reproducibility (≤20% variability), assay time (≤5 minutes), and other studies that are typically required for FDA approval. Clinical studies with production equivalent tests will be initiated upon completion of this Phase.PROJECT NARRATIVE Cyanide poisoning has been recognized as a threat from smoke inhalation and potentially through weapons of mass destruction, but there are currently no point-of-care methods available to rapidly detect cyanide levels in blood from at-risk patients. The objective of the proposed work is to complete the development and verify the performance of a field- deployable, fully integrated test device for the rapid and early detection and diagnosis of cyanide poisoning in whole blood using a cobinamide-based optical sensor in a microfluidic cartridge. Successful completion of this project will eventually enable the commercialization of the cyanide sensor which provides first-responders and healthcare professionals with a diagnostic tool to rapidly assess the extent of cyanide poisoning in exposed individuals and to effectively administer antidotes.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

3 SBIR/STTR records share this UEI (2011–2019). Reported award amounts total $4,239,251. Reported amounts are not federal obligations.

Phases: Phase II, Phase I

Agencies: Department of Health and Human Services

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.