SBIR/STTR Research Award

Development of a Field-Deployable Device to Rapidly Measure Blood Cyanide Levels

Award identifier f2d688f732719e4ea642712725e3fa014716e760263c2477ae44fe3622cf01f6Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$287,083

Program and phase

SBIR · Phase I

Award year

2011

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
DIAGNOSTIC CONSULTING NETWORK, LLC
Proposal award date
Not reported
Contract end date
Not reported
UEI
HDHMAZK2SZV4
Solicitation number
PA10-050
Topic code
NINDS

Research abstract

DESCRIPTION (provided by applicant): The objective of this proposal is to assess the feasibility of a fully integrated device for the rapid and early diagnosis of cyanide poisoning in whole blood using the spectral shift of the vitamin B12 precursor cobinamide upon binding with cyanide as an indicator. Cyanide is an extremely potent and rapid acting poison with as little as 50 mg fatal to humans. Currently there are no portable rapid tests for the detection of cyanide in whole blood available. The primary goal of this proposal is to demonstrate feasibility of the cobinamide-cyanide chemistry in a rapid test using a whole blood sample from a finger-stick. The total assay time from the sample collection to a valid result will be less than 5 minutes. The innovation in this proposal is to incorporate the cobinamide chemistry with blood separation technology, fluid path designs, and a detection area, all integrated in a compact, disposable device which can be interpreted with a handheld visualization system. Feasibility work of this novel rapid assay for detecting blood cyanide through cobinamide will initially focus on several technical approaches for the device design. Parallel paths to pursue a wet chemistry design, a design where the reagents are dried in the device, and a combination thereof will be considered, compared and evaluated. In all of the proposed methods the whole blood sample will be added to the device, followed by an integrated whole blood processing step to yield a plasma sample. Either prior toor immediately after the whole blood separation and lysis, the sample will be mixed with the on-board reagent, dried or wet, and possibly buffers. The processed sample-reagent mixture then moves through the device through various fluid paths to a detectionarea. To allow for sufficient mixing time between the sample and the reagents, different fluid paths, mixing chambers, polymeric time-gates, and dissolvable films will be evaluated with the goal of maximizing the interaction time. The spectral shift of cobinamide upon binding of cyanide to cobinamide will be measured in the detection area using a handheld or small, portable reader instrument. Upon successful completion of this Phase 1 project we intend to further develop our concept/prototype assay, complete the device design and integrate the finished test with a reader instrument through a Phase 2 proposal. Specific aims for a Phase 2 of this project include the validation of the cobinamide-based device for measuring cyanide in blood. Results will be compared to two established methods for measuring cyanide in biological samples. The sensitivity, specificity, accuracy, precision, and reproducibility of the devices will be determined. Additional studies will be designed to obtain regulatory approval and subsequently we will commercialize the test. If successful, this test will provide the medical community and first responders with a fast, reliable and economic alternative to determine cyanide poisoning. PUBLIC HEALTH RELEVANCE: Cyanide poisoning hasbeen recognized as a threat from smoke inhalation and potentially through weapons of mass destruction, but there are currently no methods available to rapidly detect cyanide in blood from at-risk patients. The objective of the proposed work is to assess the feasibility of a fully integrated method for the rapid and early detection and diagnosis of cyanide poisoning in whole blood using the spectral shift of the vitamin B12 precursor cobinamide upon binding with cyanide as an indicator. Successful accomplishment of the goals of this project will be the basis for the development of a test to detect and measure cyanide blood poisoning which will allow healthcare providers to treat patients quickly and effectively.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

3 SBIR/STTR records share this UEI (2011–2019). Reported award amounts total $4,239,251. Reported amounts are not federal obligations.

Phases: Phase II, Phase I

Agencies: Department of Health and Human Services

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.