SBIR/STTR Research Award

High-resolution ultrasonic imaging of dose distribution in clinical gel dosimeter

Award identifier 493fd11285102c294b3ff0478f286a3943afee977b614c9e0ca93c3db7cd3e5dAwarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$99,469

Program and phase

SBIR · Phase I

Award year

2008

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
LUNA INNOVATIONS INCORPORATED
Proposal award date
Not reported
Contract end date
Not reported
UEI
SJHFCDGKJJC5
Solicitation number
PHS2007-2
Topic code
Not reported

Research abstract

DESCRIPTION (provided by applicant): Title: High-resolution ultrasonic imaging of dose distribution in clinical gel dosimeters Short title: Ultrasonic imaging of dose distribution Project summary Luna Innovations in partnership with Carilion Health System proposes to develop and test a high-resolution ultrasonic technique for non-invasive 3D characterization of absorbed dose distributions in clinical gel dosimeters. Radiation-induced degradation of gel properties is an efficient way to capture spatial dose distribution that can be revealed via post processing. The ability to store 3D dose information is a clear advantage over conventional dosimetry techniques, such as water calorimetry, ion chambers, and film-based methods. However, currently deployed post-p rocessing methods using magnetic resonance imaging and optical tomography are expensive and require lengthy off-site processing. The proposed method is based on accurate ultrasonic signal phase measurement technology that can detect changes in sound speed caused by variations in material properties with better than 20 parts per billion precision. It will offer low-cost, near-real-time, on-site interpretation of dose information stored in gel with very high spatial resolution and dose accuracy. In Phase I we will assemble a proof-of concept ultrasonic scanning system, prepare gel samples with dose distribution memory, and collect ultrasonic through-transmission signals according to the fan beam tomographic geometry on several custom gel samples subjected to i onizing radiation in clinical environment. We will reconstruct spatial distributions of absorbed dose and compare them to the actual dose measured with a conventional scanning ion chamber technique. We will also study the spatial resolution and dose sensit ivity of the method as well as its ability to correctly handle refraction and boundary transition artifacts. In Phase II we will develop a circular transducer array-based portable prototype for clinical testing and optimize formulation of a radiation sensi tive gel for ultrasonic assessment. An array-based prototype will allow for rapid imaging of dose distribution in standardized gel samples with minimum of equipment - potentially a single box with USB link to a laptop. The new technology will address the n eed for quick and accurate on-site calibration of modern radiation treatment equipment, resulting in increased throughput and efficiency of future cancer treatment procedures. Title: High-resolution ultrasonic imaging of dose distribution in clinical gel d osimeters Short title: Ultrasonic imaging of dose distribution Relevance: The proposed ultrasonic characterization of absorbed dose in polymer gel phantoms will enable rapid and accurate on-site calibration of modern radiation treatment equipment and help increase throughput and efficacy of future cancer treatment procedures. The ultimate goal is to provide accurate beam profile measurement in real time to interactively adjust multileaf collimator settings.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Research funding history

994 SBIR/STTR records share this UEI (1991–2026). Reported award amounts total $336,438,763. Reported amounts are not federal obligations.

Phases: Phase I, Phase II, Phase II – Direct to Phase II

Agencies: Department of Defense, National Aeronautics and Space Administration, Department of Energy, Department of Health and Human Services, National Science Foundation, Environmental Protection Agency

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.