SBIR/STTR Research Award

Improving Electronic Circuit and System Reliability Using Embedded Prognostics

Award identifier 18f10b986cb81f21469aaf30f1e41d75b889f0df0e03504534aec8edcd0f2c0aAwarding agency Department of Energy

Award amount

$100,000

Program and phase

SBIR · Phase I

Award year

2001

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Energy
Branch
Not reported
Recipient company
Aguila Technologies, Inc.
Proposal award date
Not reported
Contract end date
Not reported
UEI
V137KTQY9GL5
Solicitation number
Not reported
Topic code
Not reported

Research abstract

65672 Manufacturing methods for CdZnTe gamma and x-ray pixel detectors, used in medical imaging, are relatively immature. One difficulty with CdZnTe as a detector material is that CdZnTe is more brittle than silicon, so standard bonding approaches frequently result in craters in the detector as well as bond failures. This has forced detector manufacturers to resort to more labor-intensive and costly indium bump bonding techniques. This project will develop mass production techniques for CdZnTe-silicon readout assemblies at low cost. The encapsulated CdZnTe-silicon assembly will be based upon previously developed pre-encapsulated flip chip fabrication technology and low-temperature soldering techniques, with particular emphasis on large quantity manufacturing at low cost. Phase I will develop, qualify, and build test assemblies of CdZnTe into silicon-based array detector electronics, adaptating the flip chip technology with a pixel pitch of 380 microns. Improvements to the solders used to assemble the devices will also be developed, and the devices will be tested at a gamma-ray imaging center. Commercial Applications And Other Benefits as described by awardee: In nuclear medicine, arrays of CdZnTe array detectors can create superior images of injected radiotracers, aiding in removal of tumors. Other applications range from mammography to brain activity monitoring. In nuclear non-proliferation, the imaging of gamma sources has the potential to detect illicit transport of fissile materials.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Research funding history

39 SBIR/STTR records share this UEI (1997–2008). Reported award amounts total $11,600,645. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Defense, Department of Health and Human Services, National Aeronautics and Space Administration, National Science Foundation, Department of Homeland Security, Department of Energy

Agency intelligence

Department of Energy

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.