SBIR/STTR Research Award

Novel tetrahedron beam CT for point-of-care imaging in ear, nose and throat imaging

Award identifier 0ddbe6c7a6ddbecf4adebe0ec6d3401bdaf47b1776bcd703bf522a067a2ff88aAwarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$1,918,925

Program and phase

STTR · Phase II

Award year

2022

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
TETRAIMAGING LLC
Proposal award date
2022-09-01
Contract end date
2024-08-31
UEI
HFW2MYZMLMP6
Solicitation number
PA21-262
Topic code
NIBIB

Research abstract

ABSTRACT Point-of-care imaging is highly desired in otolaryngologic clinics for the diagnosis of ear, nose and throat (ENT) diseases including cancers. Due to limited image quality, current cone-beam CT (CBCT) products act not as a substitute but rather as a complement to diagnostic Multi-slice CT (MSCT) in maxillofacial and ENT imaging. The emerging multi-source x-ray source technology suggests new designs of CT systems that may have faster imaging speed, improved image quality, reduced radiation exposure, and compact geometries. Tetrahedron Beam Computed Tomography (TBCT) is a compact volumetric CT based on linear array multi- pixel x-ray sources which can produce diagnostic-quality volumetric images but in a much more compact geometry than CBCT. During Phase I study, we successfully developed a benchtop ENT-TBCT system using a multi-pixel thermionic emission x-ray (MPTEX) source developed in-house and a state-of-art commercial photon-counting detector (PCD), and demonstrated the superior image quality that TBCT can achieve. During the Phase II study, we will further refine the MPTEX source and develop a clinical prototype system. To achieve this goal, we propose to perform studies to achieve the following Specific Aims (SA): SA 1: To develop a rotatable sealed MPTEX source; SA 2: To develop a clinical ENT-TBCT prototype on a rotating gantry; and SA 3: To develop advanced image reconstruction algorithm and perform benchmark imaging studies. The outcome of this research will be a highly effective point-of-care diagnostic imaging modality for otolaryngologic clinics. Future commercialization of the ENT-TBCT system will improve the quality and efficacy by supporting prompt diagnosis and treatment of ENT cancers and other diseases.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

6 SBIR/STTR records share this UEI (2011–2024). Reported award amounts total $5,010,400. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Health and Human Services

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.