Research abstract
Pediatric patients with severe heart failure require a ventricular assist device (VAD). The paracorporeal
Berlin Heart EXCOR is still the only FDA-approved VAD for pediatric patients. This diaphragm displacement
pump is small/light weight to facilitate ambulation. However, EXCOR withdraws and pumps blood at different
times for interrupted pulsatile blood flow, with its drainage and infusion cannulas functioning only half the time
(50% efficiency). EXCOR also generates a high peak blood flow rate, which may cause blood damage. A
paracorporeal continuous flow (PediMag/CentriMag) VAD has also been used with Berlin Heart cannulas in
smaller children, but its bulky/heavy motor hinders ambulation. Pediatric paracorporeal VADs require two
separate cannulas for withdrawal and infusion and their installation requires an invasive median sternotomy,
which complicates later surgery for heart transplant or repair. Our ultimate goal is to develop a minimally
invasive, high efficiency paracorporeal pulsatile diaphragm displacement VAD system for pediatric patents.
The enabling technology is a transapical double lumen cannula (DLC) with integrated compliance chambers
that features: 1) Single transapical cannulation via less invasive, small left thoracotomy; 2) Two integrated
compliance chambers that: a) Continuously withdraw/infuse blood to increase efficiency for higher blood flow
rates; b) Adjust continuous flow fluctuation for desired pulsatility; c) Reduce peak blood flow rate to mitigate
blood trauma; d) Reduce infusion lumen peak pressure, decreasing pump afterload to enhance pump output;
e) Allow smooth withdrawal to infusion transition for high frequency pumping. Bench testing of an initial
transapical DLC with integrated compliance chambers prototype with EXCOR showed double pumping flow
with decreased peak pump flow. The Phase I SBIR objective: We will redesign a transapical DLC with optimal
minimal compliance chambers and conduct performance testing in lambs. Specific Aim 1: To design,
fabricate, and bench test the high efficiency, transapical DLC with integrated compliance chambers.
The transapical DLC compliance chambers will be integrated into the drainage and infusion outlets. The 24 Fr
main DLC body will be one-piece reinforced polyurethane. The super-elastic silicone compliance chambers will
be very small with 50% stroke volume. The final prototype will be tested for 1 week in an EXCOR mock loop
with 37% glycerin for performance/reliability/durability. Specific Aim 2: To test the new 24 Fr transapical
DLC with compliance chambers in an EXCOR VAD circuit in lambs (n=8). These lamb (10-15 kg) studies
will investigate ease of transapical deployment, 6 hr in vivo performance/reliability, and initial biocompatibility.
Prototype design/fabrication/bench testing will be done at W-Z Biotech, and the animal studies will be done at
the University of Kentucky. Upon completion, the commercialized transapical DLC with integrated compliance
chambers will provide a less invasive paracorporeal pulsatile VAD with doubled efficiency. This technology can
also be used in adults and may significantly impact cardiogenic shock/bridge to heart transplant management.
Technology keywords
Not reported
Other awards by this recipient
Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.
Awards with the same topic code
Verified by an exact topic code match. This is not a text-similarity match.
Research funding history
10 SBIR/STTR records share this UEI (2011–2024). Reported award amounts total $6,885,758. Reported amounts are not federal obligations.
Phases: Phase I, Phase II
Agencies: Department of Health and Human Services
Agency intelligence
Department of Health and Human Services
Back to SBIR/STTR Research Awards