SBIR/STTR Research Award

Development of a Minimally Invasive Single Cannulation, Compact Single Port Pulsatile Ventricular Assist Device (sppVAD) for Total LV Support

Award identifier e087894db87fa2133238d1ae8f73e4fc250e87d3bb6ab6d450fc4ccd8e2b6697Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$225,000

Program and phase

SBIR · Phase I

Award year

2021

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
W-Z BIOTECH LLC
Proposal award date
2021-04-01
Contract end date
2022-09-30
UEI
RK1ZDCXE3LJ7
Solicitation number
PA20-260
Topic code
NHLBI

Research abstract

Cardiogenic shock (CS) is a serious condition of reduced cardiac output (CO) with a mortality as high as 40-50%. In severe CS, end organ hypoperfusion from low CO causes multi-organ failure and elevated left ventricle (LV) preload increases LV wall stress. For severe CS, venoarterial extracorporeal membrane oxygenation is most often used and is fastest way to reestablish circulation, but it fails to unload LV in andgt; 50% of these patients. Percutaneous mechanical circulatory support (MCS) devices are used in severe CS but may not fully stabilize circulation. Non-percutaneous MCS devices supply total cardiac support but require open chest surgery for installation. Our goal is to develop a compact, single port, pulsatile ventricular assist device (sppVAD) for total LV support that employs a minimally invasive single cannulation technique for implantation. Compared to a continuous flow LVAD, our sppVAD system may further unload the LV when synchronized with the native heart for counterpulsation. Our enabling technologies that form the sppVAD system are a valved single lumen cannula (VSLC) and a valveless single port diaphragm displacement pump (spDDP). Our innovative sppVAD system features: 1) Minimally invasive trans-apical to aorta installation by one VSLC cannulation through small left thoracotomy; 2) Smaller spDDP without inlet/outlet valves and large dead space; 3) Lower blood resistance due to shorter pathway through LV via the VSLC that serves as both inlet and outlet cannula; 4) Dependable total LV unloading; 5) Potential LV internal/stroke work decrease with counterpulsation pumping. W-Z Biotech made an initial prototype of sppVAD system, which had 3.1 L/min pumping flow against 80 mm Hg afterload in mock loop testing. Our objective in this Phase I SBIR is to develop/fabricate new working prototype of sppVAD system (VSLC and spDDP) and to test sppVAD system prototype in mock loop and severe CS sheep model. Specific Aim 1: To develop/fabricate/bench test new working prototype of sppVAD system (VSLC and spDDP). The 22 Fr VSLC main body will be memory alloy wire reinforced polyurethane (PU). Two one-way inlet valves on VSLC wall will be in LV for blood withdrawal. Two one-way outlet valves on VSLC wall near tip and a one-way outlet valve on VSLC tip will be in ascending aorta for blood delivery. The spDDP will have rigid PU housing, a soft, flexible PU diaphragm membrane, and a 50 mL pump volume. Only one 3/8” blood port will be made on spDDP for direct connection to VSLC. This sppVAD system will be tested in a bench mock loop. Specific Aim 2: To test sppVAD system prototype in a severe CS sheep model. Our severe CS sheep model will be used to test our sppVAD system prototype for ease of insertion/deployment, LV unloading performance, counterpulsation capacity, and 6 hr reliability (n=5). The sppVAD system prototype design/fabrication/in vitro testing will be done at W-Z Biotech while the in vivo animal studies will be done at University of Kentucky. Upon project completion, the commercialized sppVAD system will provide total LV support to severe CS patients via only a minimally invasive single cannulation.We are proposing to develop a compact, single port, pulsatile ventricular assist device (sppVAD) for total left ventricle (LV) support that employs a minimally invasive single cannulation technique for implantation. Our enabling technologies that form the sppVAD system are a valved single lumen cannula (VSLC) and a valveless single port diaphragm displacement pump (spDDP). Our sppVAD system will provide total LV support via only a minimally invasive single cannulation to bridge the severe cardiogenic shock patient to recovery, further treatment, long-term LVAD or heart transplantation, potentially improving outcomes.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

10 SBIR/STTR records share this UEI (2011–2024). Reported award amounts total $6,885,758. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Health and Human Services

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.