SBIR/STTR Research Award

Development of a TransApical to Aorta Double Lumen Cannula for a Neonate LVAD

Award identifier a8c4e360acee98a6d293610752b7f50ff9fc5438895b24dbbad68ad9822524f2Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$1,497,167

Program and phase

SBIR · Phase II

Award year

2018

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
W-Z BIOTECH LLC
Proposal award date
2018-09-20
Contract end date
2020-07-31
UEI
RK1ZDCXE3LJ7
Solicitation number
PA17-302
Topic code
NHLBI

Research abstract

Left ventricular assist deviceLVADsupport allows the neonate with congenital heart disease or cardiomyopathy to grow to a larger body weight that is more feasible for complex surgical correction or heart transplantThe Berlin Heart ExCORis FDA approved for pediatric LVAD applicationAlthough this device is outside the bodythe outflow graft may still create coronary artery heart compressionOur ultimate goal is to develop a less invasive and dependable LVAD system for the neonate as well as older pediatric patientsThe enabling technology is a double lumen cannulaDLCwhich is inserted from the apex into the aortaCoupled with an existing blood pumpthis DLC withdraws blood from the LV and delivers blood into the aortaunloading the LVOur DLC based LVAD only requires a one siteless invasive apex cannulationThe advantages areno outflow graft and associated heart coronary artery compressionno need of cardiopulmonary bypass and associated blood transfusionreserves more invasive sternotomy for future complex heart surgeryThis transapical to aortaTAADLC enables a high performance paracorporealextracorporeal LVAD and allows addition of a gas exchanger for cyanotic heart diseaseOur Phase I study proved that the TAA DLC based neonate LVAD system was very easy to implant via a small left thoracotomy and efficiently unloaded the LV forhours with no increase in free hemoglobin and no decrease in hemoglobin and platelet countsPhase II SBIR objectiveBased on the Phase I resultswe will optimize the design and fabricate a final commercial quality TAA DLC prototype for even smaller neonate application and forday survival lamb studiesSpecific AimTo designfabricateand bench test the high efficiencycommercial quality TAA DLC prototype for smaller neonate application and forday survival in vivo lamb studiesThe TAA DLC will be made of one piece reinforced polyurethaneComputational fluid dynamics will be used to optimize the DLC designA DLC anchoring system will be also developed to secure TAA DLC on apex and chest wall for long term ambulatory useAFrFr TAA DLC will be developed forkg neonate lamb acute study and aFrFr TAA DLC will developed forweek old lambkgsurvival studyThe final prototype will be tested for performancereliabilityand hemolysisThirty day durability will be tested inglycerinSpecific AimTo test newFr TAA DLC based LVAD inkg neonate lambnThishour study is designed to prove TAA DLC suitable for clinical neonate LVAD applicationWe will investigate ease of TAA deployment and in vivo performanceas well as potential aortic valve obstruction by extension infusion cannulaSpecific AimTo test the TAA DLC prototype fordays LVAD application inweeks old neonate lambnTheweek old lamb is still considered a neonate but almost fully weanedallowing us to performday survival studyThis in vivo study will test performancereliabilitydurabilityand biocompatibilityUpon this SBIR grant completionthe commercialized TAA DLC will provide a less invasive neonate LVAD We are proposing to develop a simpleless invasive double lumen cannula based left ventricular assist deviceLVADfor the neonate as well as older pediatric patientsThe enabling technology is the novel double lumen cannula which is coupled with a blood pump to form a LVAD system to provide total left ventricular supportthereby saving the lives of sick neonates and older pediatric patientsThis neonate LVAD system will bridge the patient to recoverytransplantor further advanced heart surgery

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

10 SBIR/STTR records share this UEI (2011–2024). Reported award amounts total $6,885,758. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Health and Human Services

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.